AI is scorching, capturing headlines, investments, and customers. It additionally runs scorching, actually: The data centers working artificial intelligence (AI) fashions use massive quantities of electrical energy and generate monumental warmth. To maintain servers from overheating, many services depend on cooling programs that use water.
AI knowledge facilities’ water use is available in two kinds. Past the water that cools the servers, knowledge facilities not directly contribute to water use by the electricity generation wanted to energy their operations. That oblique use typically makes up 80 percent or more of the general water use.
Decreasing AI’s water footprint means tackling two very completely different points—what occurs inside the information middle partitions, and what occurs past them on the power grid.
Direct Water Use: Native and Typically Disturbing
Simply as human our bodies cool themselves by sweating, knowledge facilities are sometimes cooled by water evaporation—a course of that dissipates warmth and ends in water being misplaced to the environment, and thus being counted as “consumed.” In lots of circumstances, the water is drawn from the identical municipal programs that provide houses and companies.
Whereas most main tech firms now disclose their direct water use, not all data centers follow suit, making the general image unclear. In current reviews, firms have estimated that between 45 percent and 60 percent of withdrawn water is consumed.
In line with a current report by Lawrence Berkeley National Laboratory, the 2023 direct water consumption by knowledge facilities in the USA—house to about 40 percent of the world’s data centers—is estimated at roughly 17.5 billion gallons. Assuming a 50 % consumption ratio, meaning 35 billion gallons of water withdrawal, or about 0.3 % of the total public water supply for the contiguous United States. The identical report tasks that the U.S. knowledge middle direct water consumption may double and even quadruple the 2023 degree by 2028.
On the nationwide degree, knowledge facilities’ water use is comparatively modest. However in some areas the place knowledge facilities are concentrated—and particularly in areas already dealing with shortages—the pressure on native water programs will be vital. Bloomberg Information reviews that about two-thirds of U.S. knowledge facilities constructed since 2022 are in high water-stress areas.
In Newton County, Georgia, some proposed knowledge facilities have reportedly requested extra water per day than the entire county uses day by day. Officers there now face robust selections: reject new tasks, require various water-efficient cooling programs, put money into expensive infrastructure upgrades, or danger imposing water rationing on residents.
The most important stress is probably not whole use, however timing. On scorching days when residents and companies want water most, knowledge middle water demand spikes too. In Arizona, a knowledge middle’s month-to-month water utilization through the summer time will be nearly twice its average level.
Oblique Water Use: Thirsty Electrical energy
The opposite a part of the equation is the electrical energy that powers knowledge facilities. In lots of locations, electrical energy—whether or not for coaching AI models in knowledge facilities or turning on a lightbulb in a house—is generated by fossil fuel-based power plants that require cooling water of their very own. The U.S. electric power sector withdraws about 11.6 gallons of water and consumes 1.2 gallons for each kilowatt-hour of electrical energy produced, putting it among the many nation’s largest water users. The water used to provide the electrical energy that powers knowledge facilities is taken into account oblique water use.
The water utilized by energy crops is usually not potable and never drawn from municipal water programs. Nonetheless, it might place stress on rivers, aquifers, and ecosystems—particularly in water-scarce areas.
For many U.S. knowledge facilities, this oblique use is considerably increased than direct onsite water use. One paper estimated that in 2023, utilizing GPT-3 to generate a single textual content output of 150 to 300 phrases consumed a total of 16.9 milliliters of water in a mean U.S. knowledge middle—2.2 ml for onsite cooling and 14.7 ml for electrical energy era. It’s probably that effectivity positive aspects in later fashions have lowered these numbers, however oblique water use nonetheless predominates.
How you can Reduce Knowledge Facilities’ Water Influence
In contrast to electrical energy, data center cooling programs are a design selection. Evaporative cooling is low-cost and environment friendly, however it might burden native provides throughout summer time heatwaves, when water is most wanted and least accessible. To handle that peak demand, knowledge facilities can construct onsite water storage or set up thermal energy storage. Upgrading water infrastructure—equivalent to increasing distribution or fixing leaks—can even assist native programs higher deal with demand spikes.
Options to evaporative cooling embody air-based and liquid-immersion cooling, utilizing recycled water to chop potable water use, and waste heat reuse to cut back cooling demand. Some superior designs recycle cooling water in a closed-loop, so no water is consumed; these “zero-water” designs get rid of the necessity to faucet into native drinking water provides. Nonetheless, many of those designs increase electrical energy demand, which in flip can improve oblique water use. Water-cooled knowledge facilities consume about 10 percent less energy than air-cooled knowledge facilities.
In immersion cooling programs, servers are submerged in a fluid that carries warmth away with out evaporating water. Jason Alden/Bloomberg/Getty Photos
In water-stressed areas, the precedence ought to be low- to zero-water cooling programs to cut back direct use, whereas investing so as to add renewables to the native grids to curb oblique water use and reduce carbon emissions from increased electrical energy demand. In wetter areas with carbon-intensive grids, precedence ought to be given to lowering energy use to decrease the general water consumption, even when meaning continued use of evaporative cooling with its increased onsite water consumption.
The fact of the intertwined water and electrical energy programs forces knowledge middle operators to navigate robust trade-offs between world local weather targets and native water wants. These selections typically aren’t easy, however till renewables dominate electrical energy grids, they might be unavoidable.
The views expressed on this article are these of the authors and don’t essentially mirror the views of their employers or affiliated establishments.